Home › HVAC › AC size calculator
AC size and BTUHow big an air conditioner do you need? Size a room unit in BTU from the ENERGY STAR chart, or a central system in tons for the whole home, and see where common unit sizes fall against your load.
Reviewed 8 October 2026
Sources: ENERGY STAR, ACCA and the Department of Energy, listed at the end of this page.
At the outdoor unit
The outdoor condenser of a central system shows its size on the nameplate. The photograph shows a typical unit on a pad beside the house.

The three detail views below enlarge parts of the same photograph. Use them with the checks underneath.

The nameplate is usually on a side panel. A number such as 36 in the model code often means 36,000 BTU, or 3 tons. Compare it with the load the calculator gives.

The disconnect box and the copper line set carry power and refrigerant to the indoor coil. A larger new unit may need different wiring or lines.

Shrubs and walls too close to the coil reduce capacity. Leave the clearance the manufacturer specifies, usually 1 to 2 feet around the sides.
For a single room, ENERGY STAR publishes a simple chart that matches floor area to cooling capacity in BTU per hour. It is the starting point for window, portable and wall units, and the calculator uses it directly.
| Room area (sq ft) | Cooling capacity (BTU per hour) |
|---|---|
| 100 to 150 | 5,000 |
| 150 to 250 | 6,000 |
| 250 to 300 | 7,000 |
| 300 to 350 | 8,000 |
| 350 to 400 | 9,000 |
| 400 to 450 | 10,000 |
| 450 to 550 | 12,000 |
| 550 to 700 | 14,000 |
| 700 to 1,000 | 18,000 |
| 1,000 to 1,200 | 21,000 |
| 1,200 to 1,400 | 23,000 |
| 1,400 to 1,500 | 24,000 |
| 1,500 to 2,000 | 30,000 |
| 2,000 to 2,500 | 34,000 |
High ceilings and a top-floor room under a hot roof are not in the ENERGY STAR chart. The calculator adds them as separate allowances so you can see their effect and leave them out if you prefer.
Central air conditioners and heat pumps are sold in tons; one ton removes 12,000 BTU of heat per hour. Residential systems run from about 1.5 to 5 tons. Whole-home mode multiplies the floor area by a cooling load per square foot for your climate, then adjusts for insulation, sun, ceiling height and occupants. Many homes land between 500 and 700 square feet per ton; hot climates and older, leaky homes need more capacity, efficient homes less.
An oversized air conditioner cools the air quickly and shuts off before it has run long enough to pull moisture out. The result is a cold, clammy room, more on-off cycles, more wear and uneven temperatures between rooms. Pick the nearest size at or just above the load; the green band on the result chart shows the sensible range.
A rule of thumb is a planning check. Contractors size central systems with the ACCA Manual J load calculation, which looks at walls, windows, insulation, orientation and air leakage room by room, and Manual S to choose equipment. A new system sized by Manual J is often smaller than the one it replaces. Price the system you need with the HVAC replacement cost calculator.
For a single room, the ENERGY STAR chart works out at roughly 20 BTU per square foot for mid-sized rooms, for example 8,000 BTU for 300 to 350 sq ft. Sun, people and a kitchen then adjust it.
In a mixed climate with average insulation, this calculator gives about 3 to 3.5 tons. Hot climates can need 4 tons or more, and well-insulated homes less. A Manual J load calculation gives the real figure.
Commonly about 500 to 700 square feet per ton, depending on climate, insulation, windows and ceiling height.
One ton equals 12,000 BTU per hour. A 3-ton system is 36,000 BTU per hour.
Yes. An oversized unit short-cycles, removes less humidity, leaves rooms clammy and wears out sooner. Choose the nearest size at or just above the calculated load.
A 150 to 250 sq ft bedroom needs about 6,000 BTU on the ENERGY STAR chart; a 300 to 350 sq ft room about 8,000 BTU. Add 10% for a very sunny room.
The ACCA standard method for working out a home’s heating and cooling load room by room. Ask a contractor for one before buying a central system.
Room sizing follows the ENERGY STAR chart and adjustments; whole-home sizing is a documented rule of thumb, with Manual J named as the professional method.
These organizations do not endorse ReplaceCost. The written policy, program rules, contractor scope and applicable law control the real result. See the full methodology for the source hierarchy and update process.
Too small never catches up; too big leaves the house cold and damp.