Find the model number
The nameplate is usually on a side panel. A number such as 36 in the model code often means 36,000 BTU, or 3 tons. Compare it with the load the calculator gives.
Home › HVAC › AC size calculator
AC size and BTUHow big an air conditioner do you need? Size a room unit in BTU from the ENERGY STAR chart, or a central system in tons for the whole home, and see where common unit sizes fall against your load.
Reviewed November 20, 2026 · Written by Mantu Kumar
Sources: ENERGY STAR, ACCA and the Department of Energy, listed at the end of this page.
2026 planning ranges
Diagram, part by part
The ac size drawing above has 9 numbered parts, from Floor area to Why oversizing hurts. Use the cards to check floor area to cool and climate zone before comparing the AC size quote and claim.
Starting point: 500–700 sq ft per ton
Sizing starts with the floor area that is actually cooled. Count heated and cooled rooms only, not the garage, unfinished basement or a porch that is closed off from the system.
What moves it: The conditioned floor area of the room or home.
On the quote: Measure only conditioned space and use the same figure the contractor uses.
Hot climates need more per sq ft
Hot and humid climates need more cooling per square foot than mild or northern ones. The same 2,000 square foot house might need 3 tons in a mixed climate and 4 tons or more in the Deep South or desert Southwest.
What moves it: Your climate zone and design temperature.
On the quote: Use your climate zone, not a national average.
Can cut the load by a ton
Good attic insulation and air sealing reduce how much heat gets in, so the house needs a smaller system. Upgrading insulation before replacing the AC can allow a smaller, cheaper unit.
What moves it: Attic insulation depth, wall insulation and air leaks.
On the quote: Note attic insulation depth and ask whether air sealing would change the size.
West glass adds the most
Sun through windows is one of the largest cooling loads. Large west- and south-facing windows add heat in the afternoon, when the AC is already working hardest.
What moves it: Window size, direction, shading and glass type.
On the quote: Count large windows in direct sun and mention any shading or low-E glass.
About 600 BTU per person
People and appliances give off heat. Each regular occupant adds roughly 600 BTU per hour, and a busy kitchen can add several thousand more.
What moves it: How many people use the space and how much cooking happens there.
On the quote: Add capacity for a busy kitchen or a room that holds many people.
12,000 BTU per hour = 1 ton
The result is shown in BTU per hour and in tons, the unit equipment is sold in. Central systems come in half-ton steps, so the result is rounded to the nearest available size.
What moves it: All of the inputs above.
On the quote: Ask for a Manual J load calculation before buying, and compare it to this estimate.
Taller ceilings add volume
Rules of thumb assume 8-foot ceilings. Vaulted or 10-foot ceilings hold more air and more wall and window area, so the room needs more cooling than its floor area suggests.
What moves it: Average ceiling height across the cooled area.
On the quote: Tell the contractor about vaulted or tall ceilings so they are counted in the load.
Adds load to upper rooms
Rooms directly under the roof get heat from a hot attic all afternoon. Upstairs bedrooms and bonus rooms often need extra capacity or better attic insulation and ventilation.
What moves it: Attic insulation, roof color and attic ventilation.
On the quote: Ask how upstairs rooms will be kept comfortable, and whether a zone or a separate system helps.
Bigger is not better
An oversized unit cools the air quickly and shuts off before it removes moisture, leaving the house cool but clammy. It also starts and stops more often, which wears it out sooner and costs more up front.
What moves it: How closely the unit matches the calculated load.
On the quote: Ask for a unit sized to the load calculation, and consider variable-speed equipment for better humidity control.
At the outdoor unit
The outdoor condenser of a central system shows its size on the nameplate. The photograph shows a typical unit on a pad beside the house.

Three parts of the same picture, each tied to a line on an AC size estimate. Use them with the checks underneath.

The nameplate is usually on a side panel. A number such as 36 in the model code often means 36,000 BTU, or 3 tons. Compare it with the load the calculator gives.

The disconnect box and the copper line set carry power and refrigerant to the indoor coil. A larger new unit may need different wiring or lines.

Shrubs and walls too close to the coil reduce capacity. Leave the clearance the manufacturer specifies, usually 1 to 2 feet around the sides.
For a single room, ENERGY STAR publishes a simple chart that matches floor area to cooling capacity in BTU per hour. It is the starting point for window, portable and wall units, and the calculator uses it directly.
| Room area (sq ft) | Cooling capacity (BTU per hour) |
|---|---|
| 100 to 150 | 5,000 |
| 150 to 250 | 6,000 |
| 250 to 300 | 7,000 |
| 300 to 350 | 8,000 |
| 350 to 400 | 9,000 |
| 400 to 450 | 10,000 |
| 450 to 550 | 12,000 |
| 550 to 700 | 14,000 |
| 700 to 1,000 | 18,000 |
| 1,000 to 1,200 | 21,000 |
| 1,200 to 1,400 | 23,000 |
| 1,400 to 1,500 | 24,000 |
| 1,500 to 2,000 | 30,000 |
| 2,000 to 2,500 | 34,000 |
High ceilings and a top-floor room under a hot roof are not in the ENERGY STAR chart. The calculator adds them as separate allowances so you can see their effect and leave them out if you prefer.
Central air conditioners and heat pumps are sold in tons; one ton removes 12,000 BTU of heat per hour. Residential systems run from about 1.5 to 5 tons. Whole-home mode multiplies the floor area by a cooling load per square foot for your climate, then adjusts for insulation, sun, ceiling height and occupants. Many homes land between 500 and 700 square feet per ton; hot climates and older, leaky homes need more capacity, efficient homes less.
An oversized air conditioner cools the air quickly and shuts off before it has run long enough to pull moisture out. The result is a cold, clammy room, more on-off cycles, more wear and uneven temperatures between rooms. Pick the nearest size at or just above the load; the green band on the result chart shows the sensible range.
A rule of thumb is a planning check. Contractors size central systems with the ACCA Manual J load calculation, which looks at walls, windows, insulation, orientation and air leakage room by room, and Manual S to choose equipment. A new system sized by Manual J is often smaller than the one it replaces. Price the system you need with the HVAC replacement cost calculator.
This page’s own answer for a mixed climate with average insulation, written out so the tonnage can be checked. One ton is 12,000 BTU per hour.
| Floor area | 2,000 sq ft |
| Mixed climate, this calculator | 3 to 3.5 tons |
| 3 tons in BTU per hour | 36,000 |
| 3.5 tons in BTU per hour | 42,000 |
| Hot climate, same floor area | 4 tons or more |
| Square feet per ton, typical band | 500 – 700 |
| Do not buy from the rule of thumb | Ask for Manual J |
An oversized unit cools the air and shuts off before it pulls moisture out. Hot climates move the same house up the band; a tight, well-insulated house moves it down. Price the equipment you actually need on the HVAC calculator. A single 300–350 sq ft room on the ENERGY STAR chart is a different problem: about 8,000 BTU, roughly 20 BTU per square foot.
A typical band of 500 to 700 square feet per ton for a mixed climate, before insulation, sun and occupancy adjustments. Hot climates need the upper end or more.
| Floor area | Tons | BTU per hour |
|---|---|---|
| 600 sq ft | 0.9 – 1.2 tons | 10,300.0 – 14,400.0 BTU/h |
| 1,000 sq ft | 1.4 – 2 tons | 17,100.0 – 24,000.0 BTU/h |
| 1,500 sq ft | 2.1 – 3 tons | 25,700.0 – 36,000.0 BTU/h |
| 2,000 sq ft | 2.9 – 4 tons | 34,300.0 – 48,000.0 BTU/h |
| 2,500 sq ft | 3.6 – 5 tons | 42,900.0 – 60,000.0 BTU/h |
| 3,000 sq ft | 4.3 – 6 tons | 51,400.0 – 72,000.0 BTU/h |
Use this only to check that a quote is in a sensible range; a load calculation should set the final size.
These questions help make sure the new system is sized for your house, not the old unit.
| Stage | Typical time | What happens |
|---|---|---|
| This calculator | 5 minutes | Rough size for planning. |
| Contractor visit | 1 – 2 hours | Measurements and inspection. |
| Load calculation | 1 – 3 days | Report with room loads. |
| Quote with sizing | 1 – 3 days | Equipment matched to the load. |
If quotes recommend very different sizes, ask each contractor to show their calculation.
Reducing the load can save on the equipment and on bills.
Sizing problems show up in comfort.
For a single room, the ENERGY STAR chart works out at roughly 20 BTU per square foot for mid-sized rooms, for example 8,000 BTU for 300 to 350 sq ft. Sun, people and a kitchen then adjust it.
In a mixed climate with average insulation, this calculator gives about 3 to 3.5 tons. Hot climates can need 4 tons or more, and well-insulated homes less. A Manual J load calculation gives the real figure.
Commonly about 500 to 700 square feet per ton, depending on climate, insulation, windows and ceiling height.
One ton equals 12,000 BTU per hour. A 3-ton system is 36,000 BTU per hour.
Yes. An oversized unit short-cycles, removes less humidity, leaves rooms clammy and wears out sooner. Choose the nearest size at or just above the calculated load.
A 150 to 250 sq ft bedroom needs about 6,000 BTU on the ENERGY STAR chart; a 300 to 350 sq ft room about 8,000 BTU. Add 10% for a very sunny room.
The ACCA standard method for working out a home’s heating and cooling load room by room. Ask a contractor for one before buying a central system.
In Florida’s hot, humid climate a common rule of thumb is about one ton (12,000 BTU) for every 400 to 550 square feet, depending on insulation, windows and shade. A 2,000 sq ft home usually lands between about 3.5 and 5 tons. Florida’s building code sizes equipment from an ACCA Manual J load calculation, and an oversized unit short-cycles and leaves the house humid, so ask the contractor for the Manual J report.
Yes. Taller ceilings add volume and wall area, which increases the load.
Good insulation and air sealing reduce the load, sometimes enough to drop a half ton or more.
Often about 2 to 3 tons in a mixed climate, but insulation, windows and climate change the answer.
Variable-speed systems adapt to the load better, which reduces the harm of slight oversizing.
Heat pumps are sized for both cooling and heating, and cold climates may need a larger or cold-climate unit.
It is only a rough guide. Insulation, window area, sun exposure, climate and air leakage can move the real load well away from the rule, which is why a room-by-room load calculation is recommended before buying.
Yes, but the upstairs is often several degrees warmer. Zoning with dampers, a second system for the upper floor, better attic insulation or extra return air can even out the temperatures.
SEER2 measures how efficiently a system cools over a season, not how much cooling it delivers. Size is set in tons or BTU per hour; efficiency affects how much electricity the system uses to deliver that cooling.
Room sizing follows the ENERGY STAR chart and adjustments; whole-home sizing is a documented rule of thumb, with Manual J named as the professional method.
These organizations do not endorse ReplaceCost. The written policy, program rules, contractor scope and applicable law control the real result. See the full methodology for the source hierarchy and update process.
Too small never catches up; too big leaves the house cold and damp.
Each tool itemizes the work, shows a planning range, and explains how age, depreciation and your deductible can change the insurance check.
Planning summary: Start with the physical replacement estimator, then run the Claim gap tool with the replacement figure, item age, expected life and deductible from your declarations page. The result is a planning estimate — not a contractor quote or coverage decision.